Description
- One button control - latest 3rd generation fully automatic measurement technology and cuff size from 22-42 cm
- Percentage Irregular Heart Beat Indicator (IHB) - can be useful in the detection of atrial fibrillation
- Clinically validation to the world recognised European Hypertension Society (ESH) 2010 protocol
- World Health Organisation (WHO) blood pressure classification indicator - for easy and clear understanding of BP reading
- Unique 5 year poroduct warranty - for complete peace of mind
The UA-767S-W is the latest 3 generation of the UA-767 series with new design and added features such as % irregular heart beat (IHB) function and an upgraded 60 memory function with average reading.
The UA-767S-W is supplied with a Latex and metal free, Wide Range SlimFit Cuff (22-42cm) giving a more comfortable user experience.
The UA-767S-W has clinical validation to the world recognized European Hypertension Society (ESH) 2010 Protocol, giving the user confidence in their readings.
A&D are a leading provider of medical devices for both home healthcare and healthcare professionals worldwide since 1979.
The quality of the UA-767S-W allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff).
The UA-767S-W provides the user a leading cost effective solution with the reassurance of advanced technology and clinical validation.
Box Contains
UA-767S-W Automatic Blood Pressure Monitor
Wide Range Cuff (22-42 cm)
Instruction Manual
4 x AA Batteries
Carry Case
Over 20% of UK adults have hypertension
Hypertension increases the risk of developing other health conditions.
Hypertension puts blood vessels under constant stress and damages the artery walls, making them weaker. This makes it more likely to develop clots due to poor blood flow. It can also damage arteries to the point of bursting or tearing, which can lead to internal bleeding.
A&D Medical
What is clinical validation?
Clinical validation is a formal study comparing the accuracy of a blood pressure monitor relative to the measurement of a clinical observer using a mercury sphygmomanometer and stethoscope on a patient.
Clinical validation is comprised of a three major components:
- Utilisation of modern protocols
- Independent verification of accuracy
- Publication in a peer-reviewed journal
Ensure the cuff is the correct size
Ensure the monitor is clinically validated
30 minutes before you take your measurement, do not exercise, do not drink coffee, caffeinated drink, or alcohol, and do not smoke. Sit quietly for 5-10 minutes to relax.
- Sit on a chair with your back straight, your legs uncrossed, and your feet flat on the floor.
- Place the cuff securely on the arm. Rest your arm on a table for support and make sure the cuff is at heart level.
- Press start. During your measurement, do not talk or move.
Wide Range Cuff
- Cuff circumference of 22-42cm
- Cuff Fit Error Indicator
- Movement Error Indicator
- 60-memory and Average Reading
AFib Indicator
- 0-24% : No Indication
- 24-49% : Grade 1
- 50-74% : Grade 2
- 74-100% : Grade 3
Prevalence of atrial fibrillation
• 66% of atrial fibrillation related strokes can be averted with treatment
• 20% of all strokes linked to AF
• 62% not prescribed anticoagulant
• People with atrial fibrillation x5 higher risk of stroke
Atrial fibrillation screening
An irregular heart rhythm is defined as a rhythm that is 15% less or 15% more than the average sinus rhythm detected during blood pressure measurement.
Atrial fibrillation has received clinical validation via a peer reviewed journal.